Eizo Coloredge CG19

VCP version: unreported
Controller manufacturer and model: unreported (VCP feature code C8 unsupported)
Firmware version: unreported (VCP feature code C9 unsupported)

Reports EDID at I2C bus address x50. Does not support DDC over I2C (bus address x37).

Does implement MCCS over USB, and appears to conform to the USB Monitor Control Class Specification. However, it appears that the more sophisticated monitor features such as LUT loading use manufacturer specific USB HID reports.

Unable to read EDID over USB, even though the HID Report for EDID can be located.

To set color related VCP feature values, Custom Color mode must be selected. If set to sRGB or Calibrated, the SETVCP command will appear to succeed, but will have no effect. (In sRGB mode, Brightness can be set, in Calibrated mode it cannot.)

Eizo EV2785

Reports EDID ad I2c bus address x.50. Does not support DDC/CI (bus address x37).

Uses USB for monitor control, but uses manufacturer-defined usage pages for communication, i.e. does not support the USB Monitor Control Class Specification.