This section explains how to provide RDMA communication capabilities to containers using SR-IOV technology in the context of building an AI cluster. This approach is applicable in both RoCE and Infiniband network scenarios.
Spiderpool uses the sriov-network-operator to provide containers with RDMA devices based on SR-IOV interfaces:
The Linux RDMA subsystem can operate in two modes: shared mode or exclusive mode:
-
In shared mode, the container can see the RDMA devices of all VF devices on the PF interface, but only the VF assigned to the container will have a GID Index starting from 0.
-
In exclusive mode, the container will only see the RDMA device of the VF assigned to it, without visibility of the PF or other VF RDMA devices. Different CNIs are used for different network scenarios:
-
In Infiniband network scenarios, the IB-SRIOV CNI is used to provide SR-IOV network interfaces to the POD.
-
In RoCE network scenarios, the SR-IOV CNI is used to expose the RDMA network interface on the host to the Pod, thereby exposing RDMA resources. Additionally, the RDMA CNI can be used to achieve RDMA device isolation.
-
This article will introduce how to set up Spiderpool using the following typical AI cluster topology as an example.
Figure 1: AI Cluster Topology
The network planning for the cluster is as follows:
-
The calico CNI runs on the eth0 network card of the nodes to carry Kubernetes traffic. The AI workload will be assigned a default calico network interface for control plane communication.
-
The nodes use Mellanox ConnectX5 network cards with RDMA functionality to carry the RDMA traffic for AI computation. The network cards are connected to a rail-optimized network. The AI workload will be additionally assigned SR-IOV virtualized interfaces for all RDMA network cards to ensure high-speed network communication for the GPUs.
-
Refer to the Spiderpool Installation Requirements.
-
Prepare the Helm binary on the host.
-
In Infiniband network scenarios, ensure that the OpenSM subnet manager is functioning properly.
-
Install a Kubernetes cluster with kubelet running on the host’s eth0 network card as shown in Figure 1. Install Calico as the default CNI for the cluster, using the host’s eth0 network card for Calico’s traffic forwarding. If not installed, refer to the official documentation or use the following commands to install:
$ kubectl apply -f https://github.com/projectcalico/calico/blob/master/manifests/calico.yaml $ kubectl wait --for=condition=ready -l k8s-app=calico-node pod -n kube-system # set calico to work on host eth0 $ kubectl set env daemonset -n kube-system calico-node IP_AUTODETECTION_METHOD=kubernetes-internal-ip # set calico to work on host eth0 $ kubectl set env daemonset -n kube-system calico-node IP6_AUTODETECTION_METHOD=kubernetes-internal-ip
-
Install the RDMA network card driver.
For Mellanox network cards, you can download the NVIDIA OFED official driver and install it on the host using the following installation command:
mount /root/MLNX_OFED_LINUX-24.01-0.3.3.1-ubuntu22.04-x86_64.iso /mnt /mnt/mlnxofedinstall --all
For Mellanox network cards, you can also perform a containerized installation to batch install drivers on all Mellanox network cards in the cluster hosts. Run the following command. Note that this process requires internet access to fetch some installation packages. When all the OFED pods enter the ready state, it indicates that the OFED driver installation on the hosts is complete:
$ helm repo add spiderchart https://spidernet-io.github.io/charts $ helm repo update $ helm search repo ofed # pelase replace the following values with your actual environment # for china user, it could set `--set image.registry=nvcr.m.daocloud.io` to use a domestic registry $ helm install ofed-driver spiderchart/ofed-driver -n kube-system \ --set image.OSName="ubuntu" \ --set image.OSVer="22.04" \ --set image.Arch="amd64"
If you want the RDMA system to operate in exclusive mode, at least one of the following conditions must be met: (1) The system must be based on the Linux kernel version 5.3.0 or later, with the RDMA module loaded. The RDMA core package provides a method to automatically load the relevant modules at system startup. (2) Mellanox OFED version 4.7 or later is required. In this case, it is not necessary to use a kernel based on version 5.3.0 or later.
-
Verify that the network card supports Infiniband or Ethernet operating modes.
In this example environment, the host is equipped with Mellanox ConnectX 5 VPI network cards. Query the RDMA devices to confirm that the network card driver is installed correctly.
$ rdma link link mlx5_0/1 state ACTIVE physical_state LINK_UP netdev ens6f0np0 link mlx5_1/1 state ACTIVE physical_state LINK_UP netdev ens6f1np1 .......
Verify the network card's operating mode. The following output indicates that the network card is operating in Ethernet mode and can achieve RoCE communication:
$ ibstat mlx5_0 | grep "Link layer" Link layer: Ethernet
The following output indicates that the network card is operating in Infiniband mode and can achieve Infiniband communication:
$ ibstat mlx5_0 | grep "Link layer" Link layer: InfiniBand
If the network card is not operating in the expected mode, enter the following command to verify that the network card supports configuring the LINK_TYPE parameter. If the parameter is not available, please switch to a supported network card model:
$ mst start # check the card's PCIE $ lspci -nn | grep Mellanox 86:00.0 Infiniband controller [0207]: Mellanox Technologies MT27800 Family [ConnectX-5] [15b3:1017] 86:00.1 Infiniband controller [0207]: Mellanox Technologies MT27800 Family [ConnectX-5] [15b3:1017] ....... # check whether the network card supports parameters LINK_TYPE $ mlxconfig -d 86:00.0 q | grep LINK_TYPE LINK_TYPE_P1 IB(1)
-
Enable GPUDirect RDMA
The installation of the gpu-operator:
a. Enable the Helm installation options:
--set driver.rdma.enabled=true --set driver.rdma.useHostMofed=true
. The gpu-operator will install the nvidia-peermem kernel module, enabling GPUDirect RDMA functionality to accelerate data transfer performance between the GPU and RDMA network cards. Enter the following command on the host to confirm the successful installation of the kernel module:$ lsmod | grep nvidia_peermem nvidia_peermem 16384 0
b. Enable the Helm installation option:
--set gdrcopy.enabled=true
. The gpu-operator will install the gdrcopy kernel module to accelerate data transfer performance between GPU memory and CPU memory. Enter the following command on the host to confirm the successful installation of the kernel module:$ lsmod | grep gdrdrv gdrdrv 24576 0
-
Set the RDMA subsystem on the host to exclusive mode under infiniband network, allowing containers to independently use RDMA devices and avoiding sharing with other containers.
# Check the current operating mode (the Linux RDMA subsystem operates in shared mode by default): $ rdma system netns shared copy-on-fork on # Persist the exclusive mode to remain effective after a reboot $ echo "options ib_core netns_mode=0" >> /etc/modprobe.d/ib_core.conf # Switch the current operating mode to exclusive mode. If the setting fails, please reboot the host $ rdma system set netns exclusive # Verify the successful switch to exclusive mode $ rdma system netns exclusive copy-on-fork on
-
Use Helm to install Spiderpool and enable the SR-IOV component:
helm repo add spiderpool https://spidernet-io.github.io/spiderpool helm repo update spiderpool kubectl create namespace spiderpool helm install spiderpool spiderpool/spiderpool -n spiderpool --set sriov.install=true
If you are a user in China, you can specify the helm option
--set global.imageRegistryOverride=ghcr.m.daocloud.io
to use a domestic image source.After completion, the installed components are as follows:
$ kubectl get pod -n spiderpool operator-webhook-sgkxp 1/1 Running 0 1m spiderpool-agent-9sllh 1/1 Running 0 1m spiderpool-agent-h92bv 1/1 Running 0 1m spiderpool-controller-7df784cdb7-bsfwv 1/1 Running 0 1m spiderpool-sriov-operator-65b59cd75d-89wtg 1/1 Running 0 1m spiderpool-init 0/1 Completed 0 1m sriov-network-config-daemon-8h576 1/1 Running 0 1m sriov-network-config-daemon-n629x 1/1 Running 0 1m
-
Configure the SR-IOV Operator to Create VF Devices on Each Host
Use the following command to query the PCIe information of the network card devices on the host. Confirm that the device ID [15b3:1017] appears in the supported network card models list of the sriov-network-operator.
$ lspci -nn | grep Mellanox 86:00.0 Infiniband controller [0207]: Mellanox Technologies MT27800 Family [ConnectX-5] [15b3:1017] 86:00.1 Infiniband controller [0207]: Mellanox Technologies MT27800 Family [ConnectX-5] [15b3:1017] ....
The number of SR-IOV VFs (Virtual Functions) determines how many PODs a network card can simultaneously support. Different models of network cards have different maximum VF limits. For example, Mellanox's ConnectX series network cards typically have a maximum VF limit of 127.
In the following example, we set up the network cards of GPU1 and GPU2 on each node, configuring 12 VFs for each card. Refer to the following configuration to set up the SriovNetworkNodePolicy for each network card associated with a GPU on the host. This setup will provide 8 SR-IOV resources for use.
# For Ethernet networks, set LINK_TYPE=eth. For Infiniband networks, set LINK_TYPE=ib $ LINK_TYPE=eth $ cat <<EOF | kubectl apply -f - apiVersion: sriovnetwork.openshift.io/v1 kind: SriovNetworkNodePolicy metadata: name: gpu1-nic-policy namespace: spiderpool spec: nodeSelector: kubernetes.io/os: "linux" resourceName: gpu1sriov priority: 99 numVfs: 12 nicSelector: deviceID: "1017" vendor: "15b3" rootDevices: - 0000:86:00.0 linkType: ${LINK_TYPE} deviceType: netdevice isRdma: true --- apiVersion: sriovnetwork.openshift.io/v1 kind: SriovNetworkNodePolicy metadata: name: gpu2-nic-policy namespace: spiderpool spec: nodeSelector: kubernetes.io/os: "linux" resourceName: gpu2sriov priority: 99 numVfs: 12 nicSelector: deviceID: "1017" vendor: "15b3" rootDevices: - 0000:86:00.0 linkType: ${LINK_TYPE} deviceType: netdevice isRdma: true EOF
After creating the SriovNetworkNodePolicy configuration, the sriov-device-plugin will be started on each node, responsible for reporting VF device resources.
$ kubectl get pod -n spiderpool operator-webhook-sgkxp 1/1 Running 0 2m spiderpool-agent-9sllh 1/1 Running 0 2m spiderpool-agent-h92bv 1/1 Running 0 2m spiderpool-controller-7df784cdb7-bsfwv 1/1 Running 0 2m spiderpool-sriov-operator-65b59cd75d-89wtg 1/1 Running 0 2m spiderpool-init 0/1 Completed 0 2m sriov-device-plugin-x2g6b 1/1 Running 0 1m sriov-device-plugin-z4gjt 1/1 Running 0 1m sriov-network-config-daemon-8h576 1/1 Running 0 1m sriov-network-config-daemon-n629x 1/1 Running 0 1m .......
Once the SriovNetworkNodePolicy configuration is created, the SR-IOV operator will sequentially evict PODs on each node, configure the VF settings in the network card driver, and then reboot the host. Consequently, you will observe the nodes in the cluster sequentially entering the SchedulingDisabled state and being rebooted.
$ kubectl get node NAME STATUS ROLES AGE VERSION ai-10-1-16-1 Ready worker 2d15h v1.28.9 ai-10-1-16-2 Ready,SchedulingDisabled worker 2d15h v1.28.9 .......
It may take several minutes for all nodes to complete the VF configuration process. You can monitor the sriovnetworknodestates status to see if it has entered the Succeeded state, indicating that the configuration is complete.
$ kubectl get sriovnetworknodestates -A NAMESPACE NAME SYNC STATUS DESIRED SYNC STATE CURRENT SYNC STATE AGE spiderpool ai-10-1-16-1 Succeeded Idle Idle 4d6h spiderpool ai-10-1-16-2 Succeeded Idle Idle 4d6h .......
For nodes that have successfully configured VFs, you can check the available resources of the node, including the reported SR-IOV device resources.
$ kubectl get no -o json | jq -r '[.items[] | {name:.metadata.name, allocable:.status.allocatable}]' [ { "name": "ai-10-1-16-1", "allocable": { "cpu": "40", "pods": "110", "spidernet.io/gpu1sriov": "12", "spidernet.io/gpu2sriov": "12", ... } }, ... ]
-
Create CNI Configuration and Corresponding IP Pool Resources
a. For Infiniband Networks, configure the IB-SRIOV CNI for all GPU-affinitized SR-IOV network cards and create the corresponding IP address pool. The following example configures the network card and IP address pool for GPU1
$ cat <<EOF | kubectl apply -f - apiVersion: spiderpool.spidernet.io/v2beta1 kind: SpiderIPPool metadata: name: gpu1-net11 spec: gateway: 172.16.11.254 subnet: 172.16.11.0/16 ips: - 172.16.11.1-172.16.11.200 --- apiVersion: spiderpool.spidernet.io/v2beta1 kind: SpiderMultusConfig metadata: name: gpu1-sriov namespace: spiderpool spec: cniType: ib-sriov ibsriov: resourceName: spidernet.io/gpu1sriov ippools: ipv4: ["gpu1-net91"] EOF
b. For Ethernet Networks, configure the SR-IOV CNI for all GPU-affinitized SR-IOV network cards and create the corresponding IP address pool. The following example configures the network card and IP address pool for GPU1
$ cat <<EOF | kubectl apply -f - apiVersion: spiderpool.spidernet.io/v2beta1 kind: SpiderIPPool metadata: name: gpu1-net11 spec: gateway: 172.16.11.254 subnet: 172.16.11.0/16 ips: - 172.16.11.1-172.16.11.200 --- apiVersion: spiderpool.spidernet.io/v2beta1 kind: SpiderMultusConfig metadata: name: gpu1-sriov namespace: spiderpool spec: cniType: sriov sriov: resourceName: spidernet.io/gpu1sriov enableRdma: true ippools: ipv4: ["gpu1-net11"] EOF
-
Create a DaemonSet application on a specified node to test the availability of SR-IOV devices on that node. In the following example, the annotation field
v1.multus-cni.io/default-network
specifies the use of the default Calico network card for control plane communication. The annotation fieldk8s.v1.cni.cncf.io/networks
connects to the 8 VF network cards affinitized to the GPU for RDMA communication, and configures 8 types of RDMA resources.NOTICE: It support auto inject RDMA resources for application, see Auto inject RDMA Resources
$ helm repo add spiderchart https://spidernet-io.github.io/charts $ helm repo update $ helm search repo rdma-tools # run daemonset on worker1 and worker2 $ cat <<EOF > values.yaml # for china user , it could add these to use a domestic registry #image: # registry: ghcr.m.daocloud.io # just run daemonset in nodes 'worker1' and 'worker2' affinity: nodeAffinity: requiredDuringSchedulingIgnoredDuringExecution: nodeSelectorTerms: - matchExpressions: - key: kubernetes.io/hostname operator: In values: - worker1 - worker2 # sriov interfaces extraAnnotations: k8s.v1.cni.cncf.io/networks: |- [{"name":"gpu1-sriov","namespace":"spiderpool"}, {"name":"gpu2-sriov","namespace":"spiderpool"}, {"name":"gpu3-sriov","namespace":"spiderpool"}, {"name":"gpu4-sriov","namespace":"spiderpool"}, {"name":"gpu5-sriov","namespace":"spiderpool"}, {"name":"gpu6-sriov","namespace":"spiderpool"}, {"name":"gpu7-sriov","namespace":"spiderpool"}, {"name":"gpu8-sriov","namespace":"spiderpool"}] # sriov resource resources: limits: spidernet.io/gpu1sriov: 1 spidernet.io/gpu2sriov: 1 spidernet.io/gpu3sriov: 1 spidernet.io/gpu4sriov: 1 spidernet.io/gpu5sriov: 1 spidernet.io/gpu6sriov: 1 spidernet.io/gpu7sriov: 1 spidernet.io/gpu8sriov: 1 #nvidia.com/gpu: 1 EOF $ helm install rdma-tools spiderchart/rdma-tools -f ./values.yaml
During the creation of the network namespace for the container, Spiderpool will perform connectivity tests on the gateway of the SR-IOV interface. If all PODs of the above application start successfully, it indicates successful connectivity of the VF devices on each node, allowing normal RDMA communication.
-
Check the network namespace status of the container.
You can enter the network namespace of any POD to confirm that it has 9 network cards.
$ kubectl exec -it rdma-tools-4v8t8 bash kubectl exec [POD] [COMMAND] is DEPRECATED and will be removed in a future version. Use kubectl exec [POD] -- [COMMAND] instead. root@rdma-tools-4v8t8:/# ip a 1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state UNKNOWN group default qlen 1000 link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00 inet 127.0.0.1/8 scope host lo valid_lft forever preferred_lft forever inet6 ::1/128 scope host valid_lft forever preferred_lft forever 2: tunl0@NONE: <NOARP> mtu 1480 qdisc noop state DOWN group default qlen 1000 link/ipip 0.0.0.0 brd 0.0.0.0 3: eth0@if356: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1480 qdisc noqueue state UP group default qlen 1000 link/ether ca:39:52:fc:61:cd brd ff:ff:ff:ff:ff:ff link-netnsid 0 inet 10.233.119.164/32 scope global eth0 valid_lft forever preferred_lft forever inet6 fe80::c839:52ff:fefc:61cd/64 scope link valid_lft forever preferred_lft forever 269: net1: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP group default qlen 1000 link/ether 3a:97:49:35:79:95 brd ff:ff:ff:ff:ff:ff inet 172.16.11.10/24 brd 10.1.19.255 scope global net1 valid_lft forever preferred_lft forever inet6 fe80::3897:49ff:fe35:7995/64 scope link valid_lft forever preferred_lft forever 239: net2: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP group default qlen 1000 link/ether 1e:b6:13:0e:2a:d5 brd ff:ff:ff:ff:ff:ff inet 172.16.12.10/24 brd 10.1.19.255 scope global net1 valid_lft forever preferred_lft forever inet6 fe80::1cb6:13ff:fe0e:2ad5/64 scope link valid_lft forever preferred_lft forever .....
Check the routing configuration. Spiderpool will automatically tune policy routes for each network card, ensuring that external requests received on each card are returned through the same card.
root@rdma-tools-4v8t8:/# ip rule 0: from all lookup local 32762: from 172.16.11.10 lookup 107 32763: from 172.16.12.10 lookup 106 32764: from 172.16.13.10 lookup 105 32765: from 172.16.14.10 lookup 104 32765: from 172.16.15.10 lookup 103 32765: from 172.16.16.10 lookup 102 32765: from 172.16.17.10 lookup 101 32765: from 172.16.18.10 lookup 100 32766: from all lookup main 32767: from all lookup default root@rdma-tools-4v8t8:/# ip route show table 100 default via 172.16.11.254 dev net1
In the main routing table, ensure that Calico network traffic, ClusterIP traffic, and local host communication traffic are all forwarded through the Calico network card.
root@rdma-tools-4v8t8:/# ip r show table main default via 169.254.1.1 dev eth0 172.16.11.0/24 dev net1 proto kernel scope link src 172.16.11.10 172.16.12.0/24 dev net2 proto kernel scope link src 172.16.12.10 172.16.13.0/24 dev net3 proto kernel scope link src 172.16.13.10 172.16.14.0/24 dev net4 proto kernel scope link src 172.16.14.10 172.16.15.0/24 dev net5 proto kernel scope link src 172.16.15.10 172.16.16.0/24 dev net6 proto kernel scope link src 172.16.16.10 172.16.17.0/24 dev net7 proto kernel scope link src 172.16.17.10 172.16.18.0/24 dev net8 proto kernel scope link src 172.16.18.10 10.233.0.0/18 via 10.1.20.4 dev eth0 src 10.233.119.164 10.233.64.0/18 via 10.1.20.4 dev eth0 src 10.233.119.164 10.233.119.128 dev eth0 scope link src 10.233.119.164 169.254.0.0/16 via 10.1.20.4 dev eth0 src 10.233.119.164 169.254.1.1 dev eth0 scope link
Confirm that there are 8 RDMA devices.
root@rdma-tools-4v8t8:/# rdma link link mlx5_27/1 state ACTIVE physical_state LINK_UP netdev net2 link mlx5_54/1 state ACTIVE physical_state LINK_UP netdev net1 link mlx5_67/1 state ACTIVE physical_state LINK_UP netdev net4 link mlx5_98/1 state ACTIVE physical_state LINK_UP netdev net3 .....
-
Confirm that RDMA data transmission is functioning properly between Pods across nodes.
Open a terminal, enter a Pod, and start the service:
# see 8 RDMA devices assigned to the Pod $ rdma link # Start an RDMA service $ ib_read_lat
Open another terminal, enter another Pod, and access the service:
# You should be able to see all RDMA network cards on the host $ rdma link # Successfully access the RDMA service of the other Pod $ ib_read_lat 172.91.0.115
For clusters using Infiniband networks, if there is a UFM management platform in the network, you can use the ib-kubernetes plugin. This plugin runs as a daemonset, monitoring all containers using SRIOV network cards and reporting the Pkey and GUID of VF devices to UFM.
-
Create the necessary certificates for communication on the UFM host:
# replace to right address $ UFM_ADDRESS=172.16.10.10 $ openssl req -x509 -newkey rsa:4096 -keyout ufm.key -out ufm.crt -days 365 -subj '/CN=${UFM_ADDRESS}' # Copy the certificate files to the UFM certificate directory: $ cp ufm.key /etc/pki/tls/private/ufmlocalhost.key $ cp ufm.crt /etc/pki/tls/certs/ufmlocalhost.crt # For containerized UFM deployment, restart the container service $ docker restart ufm # For host-based UFM deployment, restart the UFM service $ systemctl restart ufmd
-
On the Kubernetes cluster, create the communication certificates required by ib-kubernetes. Transfer the ufm.crt file generated on the UFM host to the Kubernetes nodes, and use the following command to create the certificate:
# replace to right user $ UFM_USERNAME=admin # replace to right password $ UFM_PASSWORD=12345 # replace to right address $ UFM_ADDRESS="172.16.10.10" $ kubectl create secret generic ib-kubernetes-ufm-secret --namespace="kube-system" \ --from-literal=UFM_USER="${UFM_USERNAME}" \ --from-literal=UFM_PASSWORD="${UFM_PASSWORD}" \ --from-literal=UFM_ADDRESS="${UFM_ADDRESS}" \ --from-file=UFM_CERTIFICATE=ufm.crt
-
Install ib-kubernetes on the Kubernetes cluster
git clone https://github.com/Mellanox/ib-kubernetes.git && cd ib-kubernetes $ kubectl create -f deployment/ib-kubernetes-configmap.yaml kubectl create -f deployment/ib-kubernetes.yaml
-
On Infiniband networks, when creating Spiderpool's SpiderMultusConfig, you can configure the Pkey. Pods created with this configuration will use the Pkey settings and be synchronized with UFM by ib-kubernetes
$ cat <<EOF | kubectl apply -f - apiVersion: spiderpool.spidernet.io/v2beta1 kind: SpiderMultusConfig metadata: name: ib-sriov namespace: spiderpool spec: cniType: ib-sriov ibsriov: pkey: 1000 ... EOF
Note: Each node in an Infiniband Kubernetes deployment may be associated with up to 128 PKeys due to kernel limitation
In the steps above, we demonstrated how to use SR-IOV technology to provide RDMA communication capabilities for containers in RoCE and Infiniband network environments. However, the process can become complex when configuring AI applications with multiple network cards. To simplify this process, Spiderpool supports classifying a set of network card configurations through annotations (cni.spidernet.io/rdma-resource-inject
). Users only need to add the same annotation to the application, and Spiderpool will automatically inject all corresponding network cards and network resources with the same annotation into the application through a webhook.
This feature only supports network card configurations with cniType of [macvlan, ipvlan, sriov, ib-sriov, ipoib].
-
Currently, Spiderpool's webhook for automatically injecting RDMA network resources is disabled by default and needs to be enabled manually.
~# helm upgrade --install spiderpool spiderpool/spiderpool --namespace spiderpool --create-namespace --reuse-values --set spiderpoolController.podResourceInject.enabled=true
After enabling the webhook automatic injection of network resources, you can update the configuration by updating the podResourceInject field in configMap: spiderpool-config.
Specify namespaces that do not require RDMA network resource injection through
podResourceInject.namespacesExclude
.Specify namespaces that require RDMA network resource injection through
podResourceInject.namespacesInclude
. If neitherpodResourceInject.namespacesExclude
norpodResourceInject.namespacesInclude
is specified, RDMA network resource injection is performed for all namespaces by default.Currently, after completing the configuration change, you need to restart the spiderpool-controller for the configuration to take effect.
-
When creating all SpiderMultusConfig instances for AI computing networks, add an annotation with the key "cni.spidernet.io/rdma-resource-inject" and a customizable value.
apiVersion: spiderpool.spidernet.io/v2beta1 kind: SpiderIPPool metadata: name: gpu1-net11 spec: gateway: 172.16.11.254 subnet: 172.16.11.0/16 ips: - 172.16.11.1-172.16.11.200 --- apiVersion: spiderpool.spidernet.io/v2beta1 kind: SpiderMultusConfig metadata: name: gpu1-sriov namespace: spiderpool annotations: cni.spidernet.io/rdma-resource-inject: rdma-network spec: cniType: sriov sriov: resourceName: spidernet.io/gpu1rdma enableRdma: true ippools: ipv4: ["gpu1-net11"]
-
When creating an AI application, add the same annotation to the application:
... spec: template: metadata: annotations: cni.spidernet.io/rdma-resource-inject: rdma-network
Note: When using the webhook automatic injection of network resources feature, do not add other network configuration annotations (such as
k8s.v1.cni.cncf.io/networks
andipam.spidernet.io/ippools
) to the application, as it will affect the automatic injection of resources. -
Once the Pod is created, you can observe that the Pod has been automatically injected with network card annotations and RDMA resources.
... spec: template: metadata: annotations: k8s.v1.cni.cncf.io/networks: |- [{"name":"gpu1-sriov","namespace":"spiderpool"}, {"name":"gpu2-sriov","namespace":"spiderpool"}, {"name":"gpu3-sriov","namespace":"spiderpool"}, {"name":"gpu4-sriov","namespace":"spiderpool"}, {"name":"gpu5-sriov","namespace":"spiderpool"}, {"name":"gpu6-sriov","namespace":"spiderpool"}, {"name":"gpu7-sriov","namespace":"spiderpool"}, {"name":"gpu8-sriov","namespace":"spiderpool"}] .... resources: limits: spidernet.io/gpu1rdma: 1 spidernet.io/gpu2rdma: 1 spidernet.io/gpu3rdma: 1 spidernet.io/gpu4rdma: 1 spidernet.io/gpu5rdma: 1 spidernet.io/gpu6rdma: 1 spidernet.io/gpu7rdma: 1 spidernet.io/gpu8rdma: 1